FRAKO Triple Safety Technology Extends the Life of Capacitors

FRAKO combines segmented film with self healing and over pressure disconnecting to offer Triple Safety protection against high energy voltage transients that can be damaging to typical capacitors. The primary objective of FRAKO’s exclusive triple safety feature is safety, but the result is also longer capacitor life.

Segmented film construction offers the highest degree of protection available against high energy internal short circuits caused by self healing events in the capacitor windings. Segmented film can safely remove a damaged section of film to protect against capacitor bursting.

FRAKO’s Dry-type capacitors eliminate the concerns of leakage and flammability associated with oil-filled capacitors, and offer enhanced protection beyond the capabilities of self-healing film alone, against severe over-voltage transients.

FRAKO Capacitors have unique features that offer superior performance and long life:

  1. Withstands harmonic current and handles maximum continuous current up to 2.25 times rated current.
  2. Self-healing film protects against typical over-voltage.
  3. Segmented film technology removes small damaged segments but retains overall capacitor integrity.
  4. Patented overpressure disconnector system completely removes all three phases of the capacitor from the electrical circuit at end of life or under severe overload.
  5. FRAKO capacitors withstand harmonics and high ambient temperatures (up to 68°C) together without derating.


Self-healing segmented capacitor film

The principle of the over 
pressure disconnector










FRAKO is committed to the highest quality standards and performs 100% capacitor testing to assure performance, quality and safety.






Thursday, May 15, 2014

Power Quality Training
For
Electrical Professionals
June 24, 25, 26, 2014
This 3-day learning event offers a combination of classroom style seminars with live demonstrations plus hands on opportunities.  This seminar, offered by Allied Industrial Marketing, Inc., will be held at the Eaton Power Systems Experience Center, near Pittsburgh, PA, which is a one-of-a-kind electrical system power quality demonstration facility.  Participants will gain a broad knowledge of power quality.


Learn, Explore & Experience PQ Problems & Solutions
Classroom Style Theory, Demonstration & Hands-on Lab

Only 24 seats available!

Don't miss this one-of-a-kind learning experience with demonstrations and a hands-on Lab!

PQ Measurements, Analysis and Problem Diagnosis
Two days of classroom style theory, applications and demonstrations are followed by a full day of training with hands-on laboratory sessions with a focus on making power quality measurements, analyzing the data and diagnosing probable causes of power quality problems. The participants will have the opportunity to use Fluke 435 Power Quality Analyzers and will learn how to make power quality measurements as well as to interpret the data.  This session teaches what to look for, where to measure and how to interpret the waveforms.  Attendees will learn how to quickly recognize specific power quality disturbances by the voltage and current waveforms.

  Power Factor 
  Harmonic Distortion
  PWM Voltage Issues
  Practical Solutions
  Real Life Examples
  More...

  3-day training program $599




Friday, March 29, 2013

CSA approval is essential when using capacitors in Canada


Having CSA approval is essential when using capacitors in Canada which shows that a product has been independently tested and certified to meet recognized standards for safety or performance.  Frako’s commitment to provide high quality capacitors to the North American Market has driven them to obtain CSA certification in addition to UL and IEC.  

FRAKO LKT Series capacitors are now certified by Canadian Standards Association (CSA file # MC 256833).  Along with CSA approval they are also UL recognized components (cURus File # 337088) and comply with IEC (IEC 831-1, -2 / EN 60831-1,-2).  The LKT Series meets or exceeds all known industry standards and surpasses the requirements of UL, CSA and EN/IEC.                                                                                                      

Capacitor ratings include 208 – 800VAC, 1 – 30 kvar of rated reactive power.   Capacitors offer high current capability to handle continuous current as high as up to 2.7 times nominal capacitor current.  FRAKO capacitors are suitable for use in continuous ambient temperatures of -40°C up to +68° C and continuous maximum case temperature of 75°C along with maximum altitude of 4000 meters.

Thursday, September 20, 2012

What’s new in Power Quality? Not the Goal! PQM-109

The goal of quality power for your facility or application is probably still the same:

·    Supply equipment with power that does not cause malfunction or damage
·    Eliminate penalties from provider or save energy costs
·    Comply with industry standards
 
Peace of Mind
What is new in power quality is the ability to model the solution before it is installed to prove the effectiveness of the solution giving you peace of mind.  This can be done at the power electronic level which is the most precise.   

Achieving the goal is sometimes difficult.  You may be faced with a decision between multiple solutions offered by well meaning manufacturers.  Which solution will truly solve your problem or meet your needs?

Now, your system can be modeled at the actual power electronic level to predict the performance of your myriad of possible solutions.  Using circuit simulation with a comprehensive power quality analysis can save you from making an expensive mistake by evaluating various alternative solutions before you buy them.  Like a test drive before you buy it… this can give you peace of mind.

Thursday, August 16, 2012

What is the function of a line reactor – for thyristor bridge PQM-108


Line reactors are commonly used in adjustable speed drive applications to improve power quality.   They are connected in series with the input terminals of the drive to serve multiple functions. 

1)   Suppress voltage transients, protect thyristors,
2)   Increase effective input impedance resulting in lower drive input harmonic current distortion and system voltage distortion, reduce true rms current, improve total (true) power factor.
5% effective impedance (at full load) yields about 35% THD-I, 3% impedance at full load results in about 45% THD-i. Note: a drive system with a 5% impedance line reactor, operating at 60% of reactor current rating will look like a 3% impedance reactor.
3)      Reduce voltage notching upstream of the line reactor. Reactor serves (along with upstream impedance, ie: transformer) as part of a voltage divider network where the notch voltage is distributed proportionately across the two impedances. To solve voltage notching, the line reactor must be connected at the input terminals of the SCR converter (ie: DC drive) that is producing the voltage notches.

Thursday, August 2, 2012

What is the function of a line reactor – for diode bridge PQM-107




Line reactors are commonly used in adjustable speed drive applications to improve power quality.   They are connected in series with the input terminals of the drive to serve multiple functions. 

1)      suppress voltage transients enabling drives with a dc bus capacitor to ride thru some system voltage disturbances, minimize O/V nuisance tripping, protect diodes from transients, protect dc bus capacitor,
2)      Increase effective input impedance resulting in lower drive input harmonic current distortion and system voltage distortion, reduce true rms current, improve total (true) power factor.
5% effective impedance (at full load) yields about 35% THD-I, 3% impedance at full load results in about 45% THD-i. Note: a drive system with a 5% impedance line reactor, operating at 60% of reactor current rating will look like a 3% impedance reactor.